With all the Mains Power cuts this year everyone is concerned with the quality of our future power supply. Is ESKOM maintaining the infrastructure sufficiently to ensure further power failures do not occur? We think not.

An Uninterruptible Power Supply (UPS), also known as an Uninterruptible Power Source, Uninterruptible Power System, Continuous Power Supply (CPS) or a battery backup is a device which maintains a continuous supply of electric power to connected equipment by supplying power from a separate source when utility power is not available. There are two distinct types of UPS: off-line and line-interactive (also called on-line).

An off-line UPS remains idle until a power failure occurs, and then switches from utility power to its own power source, almost instantaneously. An on-line UPS continuously powers the protected load from its reserves (usually lead-acid batteries or stored kinetic energy), while simultaneously replenishing the reserves from the AC power.

The on-line type of UPS, in addition to providing protection against complete failure of the utility supply, provides protection against all common power problems, and for this reason it is also known as a power conditioner and a line conditioner.

While not limited to safeguarding any particular type of equipment, a UPS is typically used to protect computers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss. UPS units come in sizes ranging from units which will back up a single computer without monitor (around 200 VA) to units which will power entire data centers or buildings (several megawatts). Larger UPS units typically work in conjunction with generators.

In certain countries, as in South Africa recently, where the electrical grid is under strain, providers struggle to ensure supply during peak demand (such as summer, when air-conditioning usage increases). To prevent unplanned blackouts, electrical utilities will sometimes use a process called rolling blackouts or load shedding, which involves cutting the power to large groups of customers for short periods of time. Several major blackouts has brought to many peoples attention the need for UPS power backup units.

A UPS should not be confused with a standby generator, which does not provide protection from a momentary power interruption and may result in an interruption when it is switched into service, whether manually or automatically. Such generators are typically placed upstream of the UPS to provide cover for lengthy outages. Integrated systems that have UPS and standby-generator components are often referred to as emergency power systems.

Common power problems

There are various common power problems that UPS units are used to correct. They are as follows (with a typical example of damage that might be caused):

  1. Power failure — Total loss of utility power: Causes electrical equipment to stop working.
  2. Voltage sag — Transient (short term) under-voltage: Causes flickering of lights.
  3. Voltage spike — Transient (short term) over-voltage i.e. spike or peak: Causes wear or acute damage to electronic equipment.
  4. Under-voltage (brownout) — Low line voltage for an extended period of time: Causes overheating in motors.
  5. Over-voltage — Increased voltage for an extended period of time: Causes light bulbs to fail.
  6. Line noise — Distortions superimposed on the power waveform: Causes electro magnetic interference.
  7. Frequency variation — Deviation from the nominal frequency (50 or 60 Hz): Causes motors to increase or decrease speed and line-driven clocks and timing devices to gain or lose time.
  8. Switching transient — Instantaneous undervoltage (notch) in the range of nanoseconds: May cause erratic behavior in some equipment, memory loss, data error, data loss and component stress.
  9. Harmonic distortion — Multiples of power frequency superimposed on the power waveform: Causes excess heating in wiring and fuses.

UPS units are divided into categories based on which of the above problems they address. Some manufacturers categorize their supplies as a level 3, 5, or 9, if they address the first 3, 5, or 9 power problems respectively.

 

Source Wikipedia.